Construction Regulations, 2014 › 12 Temporary works
Construction Regulations 12(3)(k)
| ID | 1080 |
|---|---|
| Citation | Construction Regulations 12(3)(k) |
| Instrument | Construction Regulations, 2014 |
| Instrument type | Regulation |
| Part | — |
| Number | 12 |
| Heading | Temporary works |
| Subsection | (3) |
| Paragraph | (k) |
| Subparagraph | — |
| Item | — |
| Text role | entry |
| Sort key | 06.0012.00160 |
| Source | GNR.84 of 7 February 2014 |
| Amended by | — |
| In force from | 2014-02-07 |
| Status | In force |
| Verified | No |
| Note | — |
| Text | upon casting concrete, the temporary works structure is left in place until the concrete has acquired sufficient strength to safely support its own weight and any imposed load, and is not removed until authorization in writing has been given by the competent person contemplated in paragraph (a); |
Sign in to edit this row or mark it verified.